L O A D I N G
blog banner

ICC ANSL A117.1-2003 PDF

Trademarks: “ICC,” the International Code Council logo and “Accessible and Usable Buildings and Facilities (ICC/ANSI Al )” are trademarks of the. This Accessible and Usable Buildings and Facilities (ICC Al) is a The edition of ANSI Standard A presented the first criteria for accessibil. Major changes/additions from ICC ANSI A – found in the edition of A 1. ICC ANSI. A – Section. ICC ANSI A –

Author: Goltikree Kazilrajas
Country: Swaziland
Language: English (Spanish)
Genre: Politics
Published (Last): 1 January 2017
Pages: 293
PDF File Size: 16.80 Mb
ePub File Size: 16.92 Mb
ISBN: 705-7-41003-313-4
Downloads: 76461
Price: Free* [*Free Regsitration Required]
Uploader: Tygokazahn

Table of Contents | ICC/ANSI A – | ICC premiumACCESS

One full, unobstructed side of the clear floor space shall adjoin or overlap an accessi- ble route or adjoin another clear floor space. A jurisdictional body that adopts or enforces regulations and standards for the design, construction, or operation of buildings and facilities.

Spout outlets of drinking fountains for standing persons shall be 38 inches mm minimum and 43 inches mm maximum above the floor. The display screen shall comply with Section Tactile characters shall be raised V 32 inch 0. Building Blocks Chapter 3. Each destina- tion-oriented elevator in a bank of elevators shall have audible and visible means for differ- entiation.

The pile shall be V 2 inch 1 3 mm maximum in height.

ANSI A117.1 (2003): Accessible and Usable Buildings and Facilities

The lower grab bar on the back wall of a bathtub required by Section Door spring hinges shall be adjusted so that from the open posi- tion of 70 degrees, the door shall move to the closed position in 1. Signs containing tactile characters shall be located so that a clear floor area 18 inches mm minimum by 18 inches mm minimum, centered on the tactile charac- ters, is provided beyond the arc of any door swing between the closed position and 45 degree open position.

Elevator car controls shall not be required to comply with Section Drive up only automatic teller machines and fare machines shall not be required to comply with Section The provisions of Chapter 3 shall apply where required by the scoping provisions adopted by the administrative authority or by Chap- ters 4 through Destination oriented elevator systems shall not be required to comply with Section A clear floor space complying with Section shall be provided.

  FROM TIN FOIL TO STEREO EVOLUTION OF THE PHONOGRAPH PDF

Operable parts of such hardware shall be 34 inches mm minimum and 48 inches mm maximum above the floor. Elevator operation shall be automatic. The use of American National Standards is completely voluntary; their existence does not in any respect preclude anyone, whether he or she has approved the standards or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not con- forming to the standards.

The level of illumination at the car controls, platform, and car threshold and landing sill shall be 5 foot-candles 54 lux mini- mum. Toe clearance shall be permitted to extend 25 inches mm maxi- mum under an element.

Existing call buttons and existing keypads shall be permitted to be located 54 inches mm maximum above the floor, measured to the centerline of the highest operable part.

State Building Code – ICC/ANSI A Code Interpretations

Diagonal curb ramps provided at marked crossings shall provide the 48 inches mm minimum clear space within the mark- ings. This standard is intended for adoption by govern- ment agencies and by organizations setting model codes to achieve uniformity in the technical design criteria in building codes and other regulations. Front loading machines shall have the bottom of the opening to the laundry compartment 1 5 inches mm mini- mum and 34 inches mm maximum above the floor.

TTYs required at a public pay telephone shall be permanently affixed within, or adjacent to, the telephone enclosure. Floors shall be designated Swinging hoistway doors shall open and close automatically and shall comply with Sections End door clear opening width shall be 32 inches mm minimum.

  6-3-5 BRAINWRITING PDF

Please first log in with a verified email before subscribing to alerts. August Third Printing: Walking surfaces that are a part of an accessible route shall comply with Section Parking spaces and access aisles shall comply with Section and have sur- face slopes not steeper than 1: Elevator door clear opening width shall comply with Table The permitted projection of the nosing shall be 1 V 2 inches 38 mm maximum over the tread or floor below.

The meaning of terms not specifically defined in this standard or in a refer- enced standard shall be as defined by collegiate dictionaries in the sense that the context implies. Where a for- ward approach is provided, the distance from the front edge of a counter within the enclo- sure to the face of the telephone shall be 20 inches mm maximum. The telephone and emergency signaling device shall comply with Section In Type A units, grab bars are not required to be installed where reinforcement com- plying with Section If the document is revised or amended, you will be notified by email.

The height of the seat shall be 17 inches mm minimum and 19 inches mm maximum above the bathroom floor, measured to the top of the seat. Where keypads are pro- vided, keypads shall be in a standard tele- phone keypad arrangement and shall comply with Section The number five key shall have a single raised dot. Aisle stairs and aisle ramps pro- vided with a handrail either at the side or within the aisle width.

Shelves shall be 40 inches mm minimum and 48 inches mm maximum above the floor.

Handrails shall not rotate within their fittings.